Minimum Requirements:
Panels may be used in curved applications, as long as the radius of the curve is not less than 4000mm Important: Install panels label-side up to ensure proper UV protection. Only neoprene washers should be used when securing panels. Long-Term Storage: Safety Instructions: Installation Instructions - Fabrication
Cut panels to desired length, using standard wood-cutting tools, such as a jig saw, circular saw, hand saw, scissors, sheers or utility knife. Installation Instructions - Fastening
Secure horizontal closure strips along cross supports and vertical closure strips along vertical beams. Make sure horizontal closure strips are cut at the correct point to form an even, consistent wave pattern along cross support when butted together. Pre-drill wood strips and panel (stopping at the beam) approximately 1.5mm larger than the fastener diameter. Change drill bit to 6mm or 8mm hex driver, and use 50mm self-drilling, self-tapping washer fasteners to secure through panel, closure strip and into the beam for adequate anchoring. Installation Instructions - Overlaps
Overlap each panel by one (1) corrugation. Attach panels to horizontal cross supports through the top wave of every second corrugation, and every 300mm to 450mm (or your local building code) running the length of your overlap, excluding the area where there is no support. Overlaps must face away from the direction of the prevailing winds. Corrugation ribs must run vertically for proper rain and snow runoff. If roof width is greater than panel length, install the higher panel to overlap on top of the lower panel to prevent water seepage. Installation Instructions - Ridge Cap Flashing
Install Ridge Cap along ridge of roof. Use 50mm fasteners to secure through ridge cap, panel and beam. Installation Instructions - Side Ridge Flashing
Install Side Ridge flashing on top of panels along any vertically-running junction with existing structure. Use 50mm fasteners to secure through flashing, panel and beam Installation Instructions - Wall Connector Flashing
Install Wall flashing on top of panels along any horizontal junction with existing structure. Use 50mm fasteners to secure through flashing, panel and beam. Back to the ROOFING page |
|||||||||||||